Display Results of Searched Sample


Sample code : JB-3
Element code : Pr
Unit : ppm

valuetechniqueyeartitle_of_literature<MAX120col.>journal<MAX120col.>volpagename<MAX80col.>
1.0XRF 1985.08Personal communication, Govern. Chem. Lab., Brisbane, AustraliaH.A.Olszowy
3.2ICPES 1985.07Personal communication, Tokyo University, JapanK.Toyoda
2.3CHROM 1987.05Personal communication, Vernadsky Inst. Geoch. Anal. Chem.,USSRB.F.Myasoedov
3.80NAA 1988.05Personal communication, Kanazawa University, JapanY.Miyamoto
3.2ICPMS 1988.08Laser ablation for direct elemental analysis of solid samples by inductively coupled plasma mass spectrometryAnalytical Sciences4403-409T.Mochizuki, A.Sakashita, H.Iwata, T.Kagaya, T.Shi
2.80ICPMS 1988.12Precise determination of rare earth elements in geological standard rocks by inductively coupled plasma source mass spectrometryAnalytical Sciences4637-643T.Hirata, H.Shimizu, T.Akagi, H.Sawatari and A.Mas
3.4ICPMS 1989.06Slurry nebulization technique for direct determination of rare earth elements in silicate rocks by inductively coupled plasma mass spectrometryAnalytical Sciences5311-317T.Mochizuki, A.Sakasita, H.Iwata, Y.Ishibashi and
3.5ICPMS 1990.06Multielement analysis of rocks with the use of geological certified reference material by inductively coupled plasma mass spectrometryAnalytical sciences6389-395N.Imai
3.7SIMS 1989.1Quantitative SIMS of rock reference samplesGeoch. J.23215-236H.Yurimoto, A.Yamashita, N.Nishida and S.Sueno
3.6ICPMS 1990Quantitative analysis of original and powdered rocks and mineral inclusions by laser ablation inductively coupled plasma mass spectrometryAnal. Chim. Acta235381-391N.Imai
2.95CHROM 1991.04Determination of thirteen rare-earth elements by high-performance liquid chromatography in thirty and of K, Rb, Cs, Sr and Ba by isotope dilution mass spectrometry in eighteen international geochemical reference samplesGeost. Newsletter15129-134S.P.Verma
3.8RNAA 1991.1Activation analysis of GSJ rock standard samples -Sedimentary rock series- (Abst.,in Japanese)1991 Annual Meet. Japan Geoch. Soc.201Y.Oura, N.Aota, S.Kosanda, Y.Miyamoto, T.Okui, Y.K
3.21ICPMS 1992Determination of trace and ultra-trace elements in 32 international geostandards by ICP-MSJour.Min.Pet.Econ.Geol87107-122T.Yoshida,S.Yamasaki and A.Tsumura
3.16IC 1992The rare-earth element content of GSJ rock reference Samples determined by gradient ion chromatographyGeochem. J.26241-249R.T.Watkins and
3.07ICPMS 1993.04Simultaneous determination of thirty-seven trace elements in twenty-eight international rock standards by ICP-MSGeost. Newsletter1781-97CD.Garbe-Schonberg
0.36ICPES 1993.09Personal Communication, Cesky Geologicky UstavI.Rubeska
3.25ICPMS 1994Personal communication,Tokyo Univ.Y.Amakawa
3.8NAA 1994Neutron Activation analysis of fufteen GSJ igneous rock reference samplesGeostandards Newsletter1865-84N.Aota,Y.Miyamoto,S.Kosanda,Y.Oura and K.Sakamoto
3.44SSMS 1994Trace element analysis of GSJ silicate reference materials:Comparison of SSMS with ICP-MS data and a critical discussion of compiled valuesFresenius.J.Anal.Chem350310-318K.P.Jochum and G.Jenner
3.44ICPMS 1994Trace element analysis of GSJ silicate reference materials:Comparison of SSMS with ICP-MS data and a critical discussion of compiled valuesFresenius.J.Anal.Chem350310-318K.P.Jochum and G.Jenner
3.15ICPMS 1996Determination of rare earth elements in sixteen silicate reference samples by ICP-MS after tm addition and ion exchange separationGeostamdards Newsletter20133-139J.A.Barrat,F.Keller,J.Amosse,R.N.Taylor,R.W.Nesbit
3.5XRF 1996Personal communication, Institut fur Geowissenschaften,GermanyFrau N.Groschopf
3.0INAA 1996A Self-Consistent Compilation of Elemental Concentration Data for 93 Geochemical Reference SamplesGeostandards Newsletter20217-245Randy L.Korotev
3.35ICPES 1997Personal communication,GFZ-Potsdam,GermanyE.Kramer and J.Erzinger
3.4ICPMS 1997Personal communication,GFZ-Potsdam,GermanyH.G.Plessen and J.Erzinger
<8XRF 1998Personal communication,GEOMAR,GermanyK.Wolf
3.12ICPMS 1998Personal communication,K.Ishida,Kyushyu,Univ,JapanK.Ishida
3.23ICPMS 1997Suppression of Matrix Effects In ICP-MS by High Power Operation of ICP:Application to Precise Determination of Rb,Sr,Y,Cs,Ba,REE,pb,Th and U at ng g Levels in Milligram Silicate Samples  Geostandards Newsletter21307-319A.Makishima and E.Nakamura
3.30ICPMS 1994Personal Communication,WSU GeoAnalytical Laboratory, USAC. Knaack, S. Cornelius and P. Hooper
2.78ICPMS 1994Personal Communication,WSU GeoAnalytical Laboratory, USAC. Knaack, S. Cornelius and P. Hooper
2.78ICPMS 2000Personarl Communication,Washington State UniversityD. Johnson
3.25ICPMS 2001Reference Materials for Geochmical Studies: New Analytical Data by ICP-MS and Critical Discussion of Reference ValuesGeostandards Newsletter2587-125P. Dulski

  • Hit number : 32