Display Results of Searched Sample


Sample code : JA-3
Element code : Pb
Unit : ppm

valuetechniqueyeartitle_of_literature<MAX120col.>journal<MAX120col.>volpagename<MAX80col.>
8XRF 1986.08Personal communication, British Geological Survey, EnglandD.J.Bland
6.7AA 1987.04Elemental concentrations in nine new Japanese rock reference samplesGeost. Newsletter1175-77S.Terashima and A.Ando
8.5XRF 1986.1Personal communication, Govern. Chem. Lab., Brisbane, AustraliaH.A.Olszowy, R.Sumner, R.Francis, J.Hegarty and S.
11XRF 1986.1Personal communication, Sheffield Univ., EnglandR.Kanaris-Sotiriou
13XRF 1987.01Personal communication, Universite de Liege, Liege, BelgiumI.Roelandts and G.Bologne
9AA 1987.02Personal communication, Vernadsky Inst. Geoch. Anal. Chem.,USSRB.F.Myasoedov
8XRF 1987.05Personal communication, Gold Fields Laboratories, Johannesburg, South AfricaNielsen D., C.J.Van Niekerk, M.B.Forsyth, P.R.Jani
6.5FAA 1987.06Determination of lead in standard rocks by graphite furnace AAS (in Japanese with English abstract)Bunseki Kagaku37112-115A.Matsumoto, Y.Saito, K.Kimura
<10AA 1987.07Personal communication, BMG, PhilippinesE.M.Macalalad
6.6OES 1988.02Personal communication, USSR Academy of Sciences Siberian BranchV.P.Afonin
7.1ICPMS 1990Rapid determination of seven trace elements in rock reference samples by ICP-MS (in Japanese with English abstract)Bunseki Kagaku3955-59T.Okai
8.09ICPMS 1992Determination of trace and ultra-trace elements in 32 international geostandards by ICP-MSJour.Min.Pet.Econ.Geol87107-122T.Yoshida,S.Yamasaki and A.Tsumura
8.5XRF 1991Quantitatie analysis of rock samples by XRFThe Rigaku-Denki.J.2228-44Goto
7.5XRF 1993Quantitative analysis of the trace elements in silicate rocks by X-ray fluorescence methodEarth ScienceT. Okudaira
6.3SSMS 1994Trace element analysis of GSJ silicate reference materials:Comparison of SSMS with ICP-MS data and a critical discussion of compiled valuesFresenius.J.Anal.Chem350310-318K.P.Jochum and G.Jenner
6.8ICPMS 1994Trace element analysis of GSJ silicate reference materials:Comparison of SSMS with ICP-MS data and a critical discussion of compiled valuesFresenius.J.Anal.Chem350310-318K.P.Jochum and G.Jenner
7.2XRF 1995Analysis of Pressed Pellets of Geological Samples Using Wavelength-Dispersive X-Ray Fluorescence SpectrometryX-ray Spectrometry24123-136H.P.Longerich
11XRF 1998Personal communication,GEOMAR,GermanyK.Wolf
8.04ICPMS 1997Suppression of Matrix Effects In ICP-MS by High Power Operation of ICP:Application to Precise Determination of Rb,Sr,Y,Cs,Ba,REE,pb,Th and U at ng g Levels in Milligram Silicate Samples  Geostandards Newsletter21307-319A.Makishima and E.Nakamura
6.7XRF 1999Development of a fused glass disc XRF facility and comparison with the pressed powder pellet technique at instituto de geociencias, Sao Paulo UniversityDepartment of Mineralogy and Geotectonic, Universidade de Sao Paulo, University of Melbourne, school of Earth Sciences, Department of ChemicalPAULO ERNESTO MORI, SHANE REEVES. CIRO TEIXIRA CORREIA AND MAUNU HAUKKA
10.7XRF 2000Quantitave chemical analyses of rocks by X-ray fluorescence spectrometry using a mixed alkali fluxDepartment of Earth Science, Faculty of ScienceK Umemoto, T Imaoka, T Yamasaki and M Owada
7.6ICPMS 2001Reference Materials for Geochmical Studies: New Analytical Data by ICP-MS and Critical Discussion of Reference ValuesGeostandards Newsletter2587-125P. Dulski
7XRF 1995Major and trace element analyses of rock samples by X-ray fluorescence spectrometry using Rh anode tubeDepartment of Geology, Faculty of Educaton, Iwate University and Institute of Mineralogy, Petrology, and Economic Geology, Tokoku University5589-110N. Tsuchiya, T. Hasenaka
8.5EXRF 2002Personal Communication, Southern Connecticut State Univ., USAT. Fleming

  • Hit number : 24
    e-mail: GSJRM