Display Results of Searched Sample


Sample code : JA-3
Element code : Nb
Unit : ppm

valuetechniqueyeartitle_of_literature<MAX120col.>journal<MAX120col.>volpagename<MAX80col.>
3.1XRF 1986.1Personal communication, Govern. Chem. Lab., Brisbane, AustraliaH.A.Olszowy, R.Sumner, R.Francis, J.Hegarty and S.
5XRF 1986.1Personal communication, Sheffield Univ., EnglandR.Kanaris-Sotiriou
2.6XRF 1986.11Personal communication, Geological Survey of JapanM.Ogasawara
3.6XRF 1987.03Personal communication, IFREMER, Centre de Brest, FranceJ.Etoubleau
8XRF 1987.04Personal communication, University of Lund, SwedenZ.Solyom
<4.6OES 1987.05Personal communication, Vernadsky Inst. Geoch. Anal. Chem.,USSRB.F.Myasoedov
<5XRF 1987.05Personal communication, Gold Fields Laboratories, Johannesburg, South AfricaNielsen D., C.J.Van Niekerk, M.B.Forsyth, P.R.Jani
<3XRF 1988.1Elemental concentrations in Japanese silicate rock standards: A comparison with the literatureGeost. Newsletter12379-389K.W.Sims, E.S.Gladney, C.Lundstrom and N.W.Bower
2.8ICPMS 1990.04Analysis of standard reference materials for Zr, Nb, Hf and Ta by ICP-MS after lithium metaborate fusion and cupferron separationGeost. Newsletter14197-206G.E.M.Hall and J.C.Pelchat
4XRF 1989.05Quantitative analysis of the trace elements in silicate rocks by X-ray fluorescence method(in Japanese with English abstract)Earth Science43180-185S.Tamura, Y.Kobayashi and K.Shuto
4EXRF 1991.06Personal communication, U.S. Geological SurveyK.Uto
2.91ICPMS 1992Determination of trace and ultra-trace elements in 32 international geostandards by ICP-MSJour.Min.Pet.Econ.Geol87107-122T.Yoshida,S.Yamasaki and A.Tsumura
2.2XRF 1992Personal Communication, Okayama University, JapanY.Orihashi
4XRF 1993Personal Communication, Far East Geological Institute, RussiaA.S.Zhitkov and A.V.Ignatyev
3.3XRF 1992Determination of twelve trace elements in twenty-seven and ten major elements in twenty-three geochemical reference samples by X-Ray fluorescence spectrometryGeost.Newsletter16301-309S.P.Verma T.Besch
4XRF 1993Quantitative analysis of the trace elements in silicate rocks by X-ray fluorescence methodEarth ScienceT. Okudaira
4XRF 1994Major, trace and rare-earth elements in fourteen GSJ reference samples. Determination by X-ray fluorescence spectrometry and inductively coupled plasma optical emission spectrometoryGeostandards Newsletter1891-100J.C.Germanique
4ICPES 1994Major, trace and rare-earth elements in fourteen GSJ reference samples. Determination by X-ray fluorescence spectrometry and inductively coupled plasma optical emission spectrometoryGeostandards Newsletter1891-100J.C.Germanique
3.8SSMS 1994Trace element analysis of GSJ silicate reference materials:Comparison of SSMS with ICP-MS data and a critical discussion of compiled valuesFresenius.J.Anal.Chem350310-318K.P.Jochum and G.Jenner
2.9ICPMS 1994Trace element analysis of GSJ silicate reference materials:Comparison of SSMS with ICP-MS data and a critical discussion of compiled valuesFresenius.J.Anal.Chem350310-318K.P.Jochum and G.Jenner
4XRF 1996Major and trace element analysis of fifteen japanese igneous reference rocks by XRFS and INAAGeostandards Newsletter2087-94John Stix,Michael P.Gorton,Eric Fontaine
3.2XRF 1992Quantitative analysis of Ba,Co,Cr and Vin silicate rocks by X-ray fluorescence methodContrib.Dept.Geol.Min.,NIigata Univ.7111-115Y.Kawano,N.Watanabe,K.Yamamoto and K.Shuto
3.5XRF 1995Analysis of Pressed Pellets of Geological Samples Using Wavelength-Dispersive X-Ray Fluorescence SpectrometryX-ray Spectrometry24123-136H.P.Longerich
3.5XRF 1997Personal communication,UNAM,MexicoRufino Lozano
6XRF 1998Personal communication,GEOMAR,GermanyK.Wolf
3.61XRF 1997Major and Trace Element Analyses of Silicate Rocks Using X-ray Fluorescence Spectrometer RIX3000The Rigaku-Denki Journal28T.Takahashi and K.Shuto
2.83ICPMS 1999Determination of Zirconium,Niobium,Hafnium and Tantalum at ng g-1 Levels in Geological Materials by Direct Nebulisation of Sample HF Solution into FI-ICP-MSGeostandards Newsletter237-20A.Makishima,E.Nakamura and T.Nakano
2.86ICPMS 1999Determination of Zirconium,Niobium,Hafnium and Tantalum at ng g-1 Levels in Geological Materials by Direct Nebulisation of Sample HF Solution into FI-ICP-MSGeostandards Newsletter237-20A.Makishima,E.Nakamura and T.Nakano
4XRF 1999X-ray fluorescence analysis of major and trace elements in silicate rocks using fused disk samplesJ.Fac.Cul.Edu.Saga Univ3133-140S.Kakubuchi,T.Ishisaka and Y.Kawano
3XRF 1999Development of a fused glass disc XRF facility and comparison with the pressed powder pellet technique at instituto de geociencias, Sao Paulo UniversityDepartment of Mineralogy and Geotectonic, Universidade de Sao Paulo, University of Melbourne, school of Earth Sciences, Department of ChemicalPAULO ERNESTO MORI, SHANE REEVES. CIRO TEIXIRA CORREIA AND MAUNU HAUKKA
2.38XRF 2000Quantitave chemical analyses of rocks by X-ray fluorescence spectrometry using a mixed alkali fluxDepartment of Earth Science, Faculty of ScienceK Umemoto, T Imaoka, T Yamasaki and M Owada
3XRF 1995Major and trace element analyses of rock samples by X-ray fluorescence spectrometry using Rh anode tubeDepartment of Geology, Faculty of Educaton, Iwate University and Institute of Mineralogy, Petrology, and Economic Geology, Tokoku University5589-110N. Tsuchiya, T. Hasenaka
3.7EXRF 2002Personal Communication, Southern Connecticut State Univ., USAT. Fleming

  • Hit number : 33