value | technique | year | title_of_literature<MAX120col.> | journal<MAX120col.> | vol | page | name<MAX80col.> |
---|---|---|---|---|---|---|---|
33 | XRF | 1985.03 | Personal communication, University of Lund, Sweden | Z.Solyom | |||
33 | XRF | 1985.1 | Elemental concentrations in Japanese silicate rock standards JA-1, JR-1 and JB-2 | Geost. Newsletter | 9 | 199-203 | N.W.Bower, E.S.Gladney, R.C.Hagan, P.E.Trujillo an |
26.9 | XRF | 1985.02 | Personal communication, IFREMER, Centre de Brest, France | J.Etoubleau | |||
31 | XRF | 1985.08 | Personal communication, Govern. Chem. Lab., Brisbane, Australia | H.A.Olszowy | |||
31.4 | XRF | 1985.01 | X-ray fluorescence analysis of trace elements in silicate rocks using fused disk samples (in Japanese with English abstract) | Sci. Repts., Dept. Geol., Kyushu Univ. | 14 | 117-127 | S.Nakada |
29 | XRF | 1985.08 | Personal communication, Franklin & Marshall College, Pennsylvania | S.A.Mertzman | |||
34 | XRF | 1985.02 | Personal communication, British Geological Survey, England | D.J.Bland | |||
28 | XRF | 1984.12 | Personal communication, Sheffield Univ., England | R.Kanaris-Sotiriou | |||
28 | XRF | 1984.12 | Personal communication, Sheffield Univ., England | R.Kanaris-Sotiriou | |||
34 | XRF | 1985.04 | Personal communication, University of Windsor, Canada | J.C.H.Huang | |||
33 | XRF | 1985.03 | Personal communication, Woods Hole Oceanographic Institution, U.S.A. | G.Thompson | |||
26.7 | PAA | 1984.11 | Personal communication, Tohoku University, Japan | T.Kato | |||
29.9 | PAA | 1985.12 | Photon-activation analysis of GSJ standard rocks | Res. Rep. Lab. Nuc. Sci. Tohoku Univ. | 18 | 336-350 | T.Yoshida and K.Aoki |
32 | XRF | 1984.12 | Personal communication, University of Southampton, England | I.W.Croudace | |||
32.0 | XRF | 1982 | Personal communication, The University of Adelaide, Australia | M.Ogasawara and J.Stanley | |||
32 | XRF | 1984.06 | Personal communication, University of Adelaide | J.Stanley | |||
36 | XRF | 1984.03 | Personal communication, DDR Zentrales Geologisches Institut, Berlin | Gotte | |||
28 | XRF | 1986.04 | Personal communication, Univ. Padova, Italy | B.Zanettin | |||
31.4 | XRF | 1986.04 | Personal communication, New Mexico Institute of Mining and Technology | P.R.Kyle | |||
31.0 | XRF | 1986.05 | Personal communication, Geological Survey of Japan | M.Ogasawara | |||
27 | ICPES | 1986.12 | Personal communication, Geological Survey of Japan | K.Kikkawa | |||
31.0 | XRF | 1987.03 | Trace element analysis of rock samples by x-ray fluorescence spectrometry, using Rh anode tube(in Japanese with English abstract) | Bull. Geol. Surv. Japan | 38 | 57-68 | M.Ogasawara |
51 | OES | 1987.05 | Personal communication, Vernadsky Inst. Geoch. Anal. Chem.,USSR | B.F.Myasoedov | |||
35 | ICPES | 1980 | The determination of major and minor elements on the two geochemical standard samples, JA-1 and JB-2, by inductively coupled plasma emission spectroscopy | Jour. Japan Assoc. Min. Pet. Econ. Geol. | 75 | 266-271 | S.Koga |
31 | XRF | 1983 | Personal communication, Univ. Liege, Bergium | I.Roelandts | |||
24 | XRF | 1988.1 | Elemental concentrations in Japanese silicate rock standards: A comparison with the literature | Geost. Newsletter | 12 | 379-389 | K.W.Sims, E.S.Gladney, C.Lundstrom and N.W.Bower |
27 | OES | 1988.02 | Personal communication, USSR Academy of Sciences Siberian Branch | V.P.Afonin | |||
34.6 | ICPMS | 1988.12 | Precise determination of rare earth elements in geological standard rocks by inductively coupled plasma source mass spectrometry | Analytical Sciences | 4 | 637-643 | T.Hirata, H.Shimizu, T.Akagi, H.Sawatari and A.Mas |
35 | XRF | 1989.03 | Personal communication, Ministry Ener. Mines., Caracas, Venezuela | H.Takeda | |||
29.1 | ICPMS | 1990.06 | Multielement analysis of rocks with the use of geological certified reference material by inductively coupled plasma mass spectrometry | Analytical sciences | 6 | 389-395 | N.Imai |
31.4 | XRF | 1989.09 | Personal communication, Okayama University, Japan | H.Yokose | |||
27.6 | SIMS | 1989.1 | Quantitative SIMS of rock reference samples | Geoch. J. | 23 | 215-236 | H.Yurimoto, A.Yamashita, N.Nishida and S.Sueno |
33.2 | ICPES | 1989 | Determination of rare-earth elements and yttrium in silicate rocks by sequential inductively-coupled plasma emission spectrometry | Talanta | 36 | 1183-1186 | P.Roychowdhury, N.K.Roy, D.K.Das and A.K.Das |
26.0 | ICPES | 1989 | Determination of rare earth elements and yttrium in rocks using the plasma ⅡICP emission spectrometer | Atomic Spectroscopy | 10 | 4- | Z.Sulcek, I.Rubeska, |
31.3 | XRF | 1989.05 | Quantitative analysis of the trace elements in silicate rocks by X-ray fluorescence method(in Japanese with English abstract) | Earth Science | 43 | 180-185 | S.Tamura, Y.Kobayashi and K.Shuto |
26.5 | ICPES | 1988 | Chemical analysis of REE and trace metals in GSJ rock reference samples by ICP | J.Japan Assoc.Min Pet.Econ.Geol | 83 | 102-106 | M.Tagiri and A.Fujinawa |
30.79 | ICPMS | 1992 | Determination of trace and ultra-trace elements in 32 international geostandards by ICP-MS | Jour.Min.Pet.Econ.Geol | 87 | 107-122 | T.Yoshida,S.Yamasaki and A.Tsumura |
30.9 | XRF | 1992 | Personal Communication, Okayama University, Japan | Y.Orihashi | |||
27.4 | XRF | 1991 | Quantitatie analysis of rock samples by XRF | The Rigaku-Denki.J. | 22 | 28-44 | Goto |
31 | XRF | 1993.04 | XRF and INAA determinations of major and trace elements in geological survey of Japan igneous and sedimentary rock stadards | Geost. Newsletter | 17 | 127-133 | R.B.Hallett and |
30 | XRF | 1993.08 | Trace element analysis of silicate rocks by XRF (part 1) | Technical report of ISEI | 12 | 1-13 | Y.Orihashi, M.Yuzuhara |
37.235 | ICPES | 1993.09 | Personal Communication, Cesky Geologicky Ustav | I.Rubeska | |||
30.86 | XRF | 1992 | XRF ANALYTICAL REPORT 2/92,Determination of Rb,Sr,Y,Zr and Ba in igneous rocks using Sc/Mo tube | GSJ Open-file Report | M.Ujiie and S.Togashi | ||
28.0 | XRF | 1992 | Determination of twelve trace elements in twenty-seven and ten major elements in twenty-three geochemical reference samples by X-Ray fluorescence spectrometry | Geost.Newsletter | 16 | 301-309 | S.P.Verma T.Besch |
27.8 | XRF | 1994 | Personal communication, Stanford Univ., USA | J.W.Sparks | |||
29 | XRF | 1994 | Major, trace and rare-earth elements in fourteen GSJ reference samples. Determination by X-ray fluorescence spectrometry and inductively coupled plasma optical emission spectrometory | Geostandards Newsletter | 18 | 91-100 | J.C.Germanique |
30 | ICPES | 1994 | Major, trace and rare-earth elements in fourteen GSJ reference samples. Determination by X-ray fluorescence spectrometry and inductively coupled plasma optical emission spectrometory | Geostandards Newsletter | 18 | 91-100 | J.C.Germanique |
25.8 | SSMS | 1994 | Trace element analysis of GSJ silicate reference materials:Comparison of SSMS with ICP-MS data and a critical discussion of compiled values | Fresenius.J.Anal.Chem | 350 | 310-318 | K.P.Jochum and G.Jenner |
26 | ICPMS | 1994 | Trace element analysis of GSJ silicate reference materials:Comparison of SSMS with ICP-MS data and a critical discussion of compiled values | Fresenius.J.Anal.Chem | 350 | 310-318 | K.P.Jochum and G.Jenner |
30 | XRF | 1996 | Major and trace element analysis of fifteen japanese igneous reference rocks by XRFS and INAA | Geostandards Newsletter | 20 | 87-94 | John Stix,Michael P.Gorton,Eric Fontaine |
32 | XRF | 1992 | Quantitative analysis of Ba,Co,Cr and Vin silicate rocks by X-ray fluorescence method | Contrib.Dept.Geol.Min.,NIigata Univ. | 7 | 111-115 | Y.Kawano,N.Watanabe,K.Yamamoto and K.Shuto |
29 | INAA | 1996 | A Self-Consistent Compilation of Elemental Concentration Data for 93 Geochemical Reference Samples | Geostandards Newsletter | 20 | 217-245 | Randy L.Korotev |
30.1 | ICPMS | 1997 | Personal communication,The Univ.of Kansas | Daniel R.Gravatt | |||
26.3 | XRF | 1995 | Analysis of Pressed Pellets of Geological Samples Using Wavelength-Dispersive X-Ray Fluorescence Spectrometry | X-ray Spectrometry | 24 | 123-136 | H.P.Longerich |
29.74 | XRF | 1997 | Major and Trace Element Analyses of Silicate Rocks Using X-ray Fluorescence Spectrometer RIX3000 | The Rigaku-Denki Journal | 28 | T.Takahashi and K.Shuto | |
32.7 | ICPMS | 1997 | Suppression of Matrix Effects In ICP-MS by High Power Operation of ICP:Application to Precise Determination of Rb,Sr,Y,Cs,Ba,REE,pb,Th and U at ng g Levels in Milligram Silicate Samples | Geostandards Newsletter | 21 | 307-319 | A.Makishima and E.Nakamura |
29 | XRF | 1999 | X-ray fluorescence analysis of major and trace elements in silicate rocks using fused disk samples | J.Fac.Cul.Edu.Saga Univ | 3 | 133-140 | S.Kakubuchi,T.Ishisaka and Y.Kawano |
30.6 | XRF | 1999 | Development of a fused glass disc XRF facility and comparison with the pressed powder pellet technique at instituto de geociencias, Sao Paulo University | Department of Mineralogy and Geotectonic, Universidade de Sao Paulo, University of Melbourne, school of Earth Sciences, Department of Chemical | PAULO ERNESTO MORI, SHANE REEVES. CIRO TEIXIRA CORREIA AND MAUNU HAUKKA | ||
31.3 | XRF | 2000 | Quantitave chemical analyses of rocks by X-ray fluorescence spectrometry using a mixed alkali flux | Department of Earth Science, Faculty of Science | K Umemoto, T Imaoka, T Yamasaki and M Owada | ||
32 | XRF | 1995 | Major and trace element analyses of rock samples by X-ray fluorescence spectrometry using Rh anode tube | Department of Geology, Faculty of Educaton, Iwate University and Institute of Mineralogy, Petrology, and Economic Geology, Tokoku University | 55 | 89-110 | N. Tsuchiya, T. Hasenaka |