Display Results of Searched Sample


Sample code : JG-1
Element code : La
Unit : ppm

valuetechniqueyeartitle_of_literature<MAX120col.>journal<MAX120col.>volpagename<MAX80col.>
21.48IDMS 1971Personal communication, Science University of Tokyo, JapanN.Nakamura and A.Masuda
26.3NAA 1971Personal communicaction, University of Osaka Prefecture, JapanY.Masuda and Yagi
18XRF 1975.01Personal communication, Service Analyse et Contro, Complexe Scientifique, Canada.J. Gagnon
22.5NAA 1974Some trace element data and their interpretation for several new reference samples obtained by neutron activation analysisChem. Geol.13237-256K.Randle
27NAA 1976Personal communication, The Open University, Walton Hall, England.P.J. Potts
19.4NAA 1976.08Personal communication, Tokyo Metoro. Isot. Res. Center JapanY.Tanizaki
22.4NAA 1982.12Heavy metal pollution in Osaka bay sediment(in Japanese with English abstract)Rep. Atom. Ener.Res. Inst., Kinki Univ.1929-36S.Gohda and H.Yamazaki
24NAA 1981.1Personal communication, Coverment Industrial Research Institute Nagoya, JapanT.Kawashima
9.3*XRF 1983Personal communication, Univ. Liege, BergiumI.Roelandts
21.5INAA 1979.03Application of instrumental neutron activation analysis for environmental samplesRep. Ministry of Educ.(1)122-124H.Hamaguchi, N.Nonaka, H.Fukushima and H.Higuchi
27.40NAA 1977.07Personal communication, Tokyo Gakugei University, JapanY.Sakakibara
21INAA 1985.1Personal communication, Tokyo Gakugei University, JapanS.Ninomiya
19XRF 1985.06Personal communication, Earth Sciences Board, University of CaliforniaJ.Gill
19.9ICPES 1985.07Personal communication, Tokyo University, JapanK.Toyoda
25INAA 1978.04Personal communication, Kanagawa Prefectural Public Health Laboratory, JapanH.Takagi and H.Sugiyama
19.9ICPES 1985Determination of rare earth elements in geological standard rock samples by inductively coupled plasma atomic emission spectrometryChemistry Letters981-984K.Toyoda and H.Haraguchi
24.6INAA 1985.1Analysis of standard rock samples by neutron activation, x-ray fluorescence and Mossbauer Methods(Abst.,in Japanese)29 Symp. Radioch.Y.Minai, M.Ebihara, K.Sakamoto, N.Aota, R.Matsumot
18.54IDMS 1986.09Personal communication, Geological Survey of JapanT.Tanaka
28.4NAA 1985.08Reevaluation of rare earth element abundances in Japanese standard rock samples, JG-1 and JB-1Analytical Sciences1209-213M.Ebihara, Y.Minai, M.K.Kubo, T.Tominaga, N.Aota,
23.75INAA 1980Comparison of different methods for activation analysis of geological and pedological samples: Reactor and epithermal neutron activation, relative and monostandard methodKFA Julich GmbH19801-46A.Alian and B.Sansoni
26.1NAA 1983The monostandard method in thermal neutron activation analysisKFA Julich GmbH19831-24A.Alian, R.G.Djingova, B.Kroner and B.Sansoni
21.2INAA 1987.1A fully automated gamma-ray counting and data data processing system for INAA and analysis of rock reference samples (in Japanese with English abstract)Bull. Geol. Surv. Japan39537-557T.Tanaka, H.Kamioka and K.Yamanaka
16.6IDMS 1984.1Precise determination of Ho in meteorite and standard rocks by isotope dilution (Abst.,in Japanese)1984 Annual Meet. Japan Geoch. Soc.138O.Kawakami and A.Masuda
22.74ICPMS 1988.03Personal communication, National Inst. Agro-Env. Sci.A.Yoshino
22.7RNAA 1989.02Precise determination of rare earth elements in rocks by neutron activation analysisJ. Radio. Nuc. Chem., Articles12923-31Y.Terakada, T.Fujitani and J.Takada
22.65ICPMS 1989.08Personal communication, Geological Survey of JapanN.Imai
21.7ICPMS 1990.06Multielement analysis of rocks with the use of geological certified reference material by inductively coupled plasma mass spectrometryAnalytical sciences6389-395N.Imai
22.5INAA 1981Determination of the rare-earth element abundances in 29 international rock standards by instrumental neutron activation analysis: A critical appraisal of calibration errorsChem. Geol.34331-352P.J.Potts, O.W.Thorpe
21.9INAA 1984.04Trace element analysis by neutron activation with a low flux reactor (slowpoke-II): Results for international reference rocksGeost. Newsletter817-23S.J.Barnes and M.P.Gorton
21.0ICPES 1988.04Determination of the rare-earth elements and yttrium in 37 international silicate reference materials by inductively coupled plasma-atomic emission spectrometryGeost. Newsletter121-12K.E.Jarvis and I.Jarvis
24.3INAA 1980Rare earth element mobility during granite alteration: evidence from southwest EnglandEarth Planet. Sci. Let.49149-165D.H.M.Alderton, J.A.Pearce and P.J.Potts
24.5INAA 1981Rare earth abundances and origin of some Indian lamprophyresGeol. Mag.118393-399D.K.Paul and P.J.Potts
21.8ICPMS 1989.1Determination of rare earth elements in geological samples by inductively coupled plasma mass spectrometryJ. Anal. Atomic Spectrometry4563-K.E.Jarvis
23ICPMS 1990Quantitative analysis of original and powdered rocks and mineral inclusions by laser ablation inductively coupled plasma mass spectrometryAnal. Chim. Acta235381-391N.Imai
22.8ICPES 1989Determination of rare earth elements and yttrium in rocks using the plasma ⅡICP emission spectrometerAtomic Spectroscopy104-Z.Sulcek, I.Rubeska,
21.4ICPES 1988Chemical analysis of REE and trace metals in GSJ rock reference samples by ICPJ.Japan Assoc.Min Pet.Econ.Geol83102-106M.Tagiri and A.Fujinawa
19.93ICPMS 1992Determination of trace and ultra-trace elements in 32 international geostandards by ICP-MSJour.Min.Pet.Econ.Geol87107-122T.Yoshida,S.Yamasaki and A.Tsumura
19.5IC 1992The rare-earth element content of GSJ rock reference Samples determined by gradient ion chromatographyGeochem. J.26241-249R.T.Watkins and
24.745ICPES 1993.09Personal Communication, Cesky Geologicky UstavI.Rubeska
22.6ICPMS 1995Analysis of rareearth elementsin standard samples of granitic rocks by inductively coupled plasma mass spectrometry after acid digestion and alkali fusionJ.Min.Petr.Econ.Geol.90419-427M.Ujiie and N.Imai

  • Hit number : 40