value | technique | year | title_of_literature<MAX120col.> | journal<MAX120col.> | vol | page | name<MAX80col.> |
---|---|---|---|---|---|---|---|
1.57 | IDMS | 1971 | Personal communication, NASA, Goddard, Maryland, U.S.A. | H.Nagasawa | |||
1.63 | IDMS | 1971 | Personal communication, Science University of Tokyo, Japan | N.Nakamura and A.Masuda | |||
1.5 | SSMS | 1976 | Analysis of JG-1 and by spark source mass spectrometry | Jour. Geol. Soc. Japan | 82 | 215-217 | P.C.Rankin |
3.0 | ICPES | 1985.07 | Personal communication, Tokyo University, Japan | K.Toyoda | |||
2.04 | IDMS | 1985.12 | Personal communication, Hokkaido University, Japan | Y.Ikeda | |||
2.96 | ICPES | 1985 | Determination of rare earth elements in geological standard rock samples by inductively coupled plasma atomic emission spectrometry | Chemistry Letters | 981-984 | K.Toyoda and H.Haraguchi | |
2.52 | IDMS | 1984.1 | Precise determination of Ho in meteorite and standard rocks by isotope dilution (Abst.,in Japanese) | 1984 Annual Meet. Japan Geoch. Soc. | 138 | O.Kawakami and A.Masuda | |
1.63 | ICPMS | 1988.03 | Personal communication, National Inst. Agro-Env. Sci. | A.Yoshino | |||
1.5 | ICPMS | 1989.08 | Personal communication, Geological Survey of Japan | N.Imai | |||
1.5 | ICPMS | 1990.06 | Multielement analysis of rocks with the use of geological certified reference material by inductively coupled plasma mass spectrometry | Analytical sciences | 6 | 389-395 | N.Imai |
3.3 | INAA | 1981 | Determination of the rare-earth element abundances in 29 international rock standards by instrumental neutron activation analysis: A critical appraisal of calibration errors | Chem. Geol. | 34 | 331-352 | P.J.Potts, O.W.Thorpe |
1.78 | ICPES | 1988.04 | Determination of the rare-earth elements and yttrium in 37 international silicate reference materials by inductively coupled plasma-atomic emission spectrometry | Geost. Newsletter | 12 | 1-12 | K.E.Jarvis and I.Jarvis |
6.47 | ICPMS | 1989.1 | Determination of rare earth elements in geological samples by inductively coupled plasma mass spectrometry | J. Anal. Atomic Spectrometry | 4 | 563- | K.E.Jarvis |
3.8 | ICPMS | 1990 | Quantitative analysis of original and powdered rocks and mineral inclusions by laser ablation inductively coupled plasma mass spectrometry | Anal. Chim. Acta | 235 | 381-391 | N.Imai |
2.54 | ICPES | 1989 | Determination of rare earth elements and yttrium in rocks using the plasma ⅡICP emission spectrometer | Atomic Spectroscopy | 10 | 4- | Z.Sulcek, I.Rubeska, |
1.96 | ICPES | 1988 | Chemical analysis of REE and trace metals in GSJ rock reference samples by ICP | J.Japan Assoc.Min Pet.Econ.Geol | 83 | 102-106 | M.Tagiri and A.Fujinawa |
1.54 | ICPMS | 1992 | Determination of trace and ultra-trace elements in 32 international geostandards by ICP-MS | Jour.Min.Pet.Econ.Geol | 87 | 107-122 | T.Yoshida,S.Yamasaki and A.Tsumura |
2.70 | IC | 1992 | The rare-earth element content of GSJ rock reference Samples determined by gradient ion chromatography | Geochem. J. | 26 | 241-249 | R.T.Watkins and |
3.045 | ICPES | 1993.09 | Personal Communication, Cesky Geologicky Ustav | I.Rubeska | |||
2.82 | ICPMS | 1995 | Analysis of rareearth elementsin standard samples of granitic rocks by inductively coupled plasma mass spectrometry after acid digestion and alkali fusion | J.Min.Petr.Econ.Geol. | 90 | 419-427 | M.Ujiie and N.Imai |