Display Results of Searched Sample


Sample code : JB-1
Element code : Dy
Unit : ppm

valuetechniqueyeartitle_of_literature<MAX120col.>journal<MAX120col.>volpagename<MAX80col.>
4.06IDMS 1971Personal communication, NASA, Goddard, Maryland, U.S.A.H.Nagasawa
4.25IDMS 1971Personal communication, Geological Suevey of Japan.T.Tanaka and A.Masuda
4.13IDMS 1974Personal communication, Geological Suevey of Japan.T.Tanaka
3.9SSMS 1976Analysis of JG-1 and by spark source mass spectrometryJour. Geol. Soc. Japan82215-217P.C.Rankin
4.0NAA 1979Apoll 15 deep drill core: Trace element and metallic iron abundances in size fractions of sample 15002, 170Proc. Lunar Planet. Sci. Conf. 10 th.1321-1332C.L. Chou and G.W. Pearce
3.8ICPES 1985.07Personal communication, Tokyo University, JapanK.Toyoda
4.19IDMS 1975Geological significance of rare earth elements in Japanese geosynclinal basaltsContrib. Mineral. Petrol.52233-246T.Tanaka
3.75ICPES 1985Determination of rare earth elements in geological standard rock samples by inductively coupled plasma atomic emission spectrometryChemistry Letters981-984K.Toyoda and H.Haraguchi
3.9INAA 1986.06Distribution of rare earth elements in basaltic rocks (in Japanese with English abstract)Proceed. Inst. Natural Sci. Nihon Univ.211-23M.Honda, H.Nagai, T.Nakasone, M.Kuboki, M.Sudoh, T
4.03IDMS 1984.1Precise determination of Ho in meteorite and standard rocks by isotope dilution (Abst.,in Japanese)1984 Annual Meet. Japan Geoch. Soc.138O.Kawakami and A.Masuda
3.8ICPMS 1988.03Personal communication, National Inst. Agro-Env. Sci.A.Yoshino
4.25ICPMS 1988.12Precise determination of rare earth elements in geological standard rocks by inductively coupled plasma source mass spectrometryAnalytical Sciences4637-643T.Hirata, H.Shimizu, T.Akagi, H.Sawatari and A.Mas
4.06ICPMS 1989.08Personal communication, Geological Survey of JapanN.Imai
4.0SIMS 1989.1Quantitative SIMS of rock reference samplesGeoch. J.23215-236H.Yurimoto, A.Yamashita, N.Nishida and S.Sueno
4.5INAA 1981Determination of the rare-earth element abundances in 29 international rock standards by instrumental neutron activation analysis: A critical appraisal of calibration errorsChem. Geol.34331-352P.J.Potts, O.W.Thorpe
5.6SIMS 1985In situ rare-earth element analysis of coexisting pyroxene and plagioclase by secondary ion mass spectrometryChem. Geol.53325-333N.D.Macrae and J.B.Metson
4.72ICPES 1988Determination of rare earth elements in geological samples by inductively-coupled plasma atomic emission spectrometry after oxalate coprecipitation and cation-exchange column separationAnal. Chim. Acta208163-172K.Iwasaki and H.Haraguchi
3.82ICPES 1988.04Determination of the rare-earth elements and yttrium in 37 international silicate reference materials by inductively coupled plasma-atomic emission spectrometryGeost. Newsletter121-12K.E.Jarvis and I.Jarvis
4.13XRF 1980Geochemistry of the upper Snooks Arm Group basalts, burlington peninsula, Newfoundland: evidence against formation in an island arcCan. J. Earth Sci.17888-900G.A.Jenner and B.J.Fryer
3.90SSMS 1981Determination of rare-earth elements in rocks by spark source mass spectrometry and isotope dilution after ion-exchange separation in mixed solventsFresenius Z. Anal. Chem.309312-315J.V.Puymbroeck and R.Gijbels
4.05IDMS 1989Volcanism in nascent back-arc basins behind the shichito ridge and adjacent areas in the Izu-Ogasawara arc, northwest Pacific: evidence for mixing between E-type MORB and island arc magmas at the initiation of back-arc riftingContrib. Mineral. Petrol101377-393Y.Ikeda and M.Yuasa
4.06ICPES 1989Determination of rare earth elements and yttrium in rocks using the plasma ⅡICP emission spectrometerAtomic Spectroscopy104-Z.Sulcek, I.Rubeska,
4.29ICPES 1988Chemical analysis of REE and trace metals in GSJ rock reference samples by ICPJ.Japan Assoc.Min Pet.Econ.Geol83102-106M.Tagiri and A.Fujinawa
4.14ICPMS 1992Determination of trace and ultra-trace elements in 32 international geostandards by ICP-MSJour.Min.Pet.Econ.Geol87107-122T.Yoshida,S.Yamasaki and A.Tsumura
4.09IC 1992The rare-earth element content of GSJ rock reference Samples determined by gradient ion chromatographyGeochem. J.26241-249R.T.Watkins and
3.89ICPMS 1997Personal communication,Koberuko Co., JapanSomeya
4.21ICPMS 1998Personal communication,K.Ishida,Kyushyu,Univ,JapanK.Ishida
4.38ICPMS 1997Suppression of Matrix Effects In ICP-MS by High Power Operation of ICP:Application to Precise Determination of Rb,Sr,Y,Cs,Ba,REE,pb,Th and U at ng g Levels in Milligram Silicate Samples  Geostandards Newsletter21307-319A.Makishima and E.Nakamura

  • Hit number : 28